Home > Product > AC R Load Bank » AC690V-90KW-R load bank
AC690V-90KW-R load bank
Product Category:AC R Load Bank
Product Number:VILVA-1038
Product Brief:AC R load bank is a device for detecting the output power and load capacity of the generator set, high power UPS power supply, inverter
Hotline:

 +86-18122867790

Product Details

AC690V-90KW-R load bank

Product Category: Test Load Series

Product specifications: VILVA-AC690V-90KW-R load bank

Description: The VILVA-AC690V-90KW-R load bank is a device for detecting the output power and load capacity of generator sets, high-power UPS power supplies, inverters.

1. The product overview

VILVA-690V-90KW-R AC load bank has built-in pure resistive load; it can simulate various power loads and meet the needs of AC power supply full load detection of generator sets, UPS power supplies, inverters, etc. It is the production workshop, laboratory, installation. Debugging, research and development necessary testing tools.

The host has a temperature overheating automatic alarm protection function: when there is overheating due to special reasons, the load can be automatically cut off. The whole machine is composed of a resistive load. The load works in energy-consuming mode, and the heat dissipation uses forced air cooling. The fan adopts a small axial flow fan, which has the characteristics of large air volume, good heat dissipation and low noise.

The above characteristics make the whole machine superior to imported products in terms of safety, reliability and noise reduction.

2., Technical parameters

Equipment technical parameters

Rated voltage

690V

Rated power

90KW

 frequency

50HZ/60HZ

Power factor

R Load:PF=1.0

Load accuracy

±5%

Load control

 local touch screen control

Control switch

Emergency stop switch/Fan switch/Load main switch/R load switch/gear position switch

Working power

single-phase AC220V 50HZ

Protection level

IP20(suitable for indoor use)

Fan noise

65 decibel

cooling method

Forced air cooling: side winds on the wind

Way of working

Can work continuously

Protective function

Forced uninstall/Over temperature protection/Over temperature alarm buzzer

Mobile mode

Prompt to install moving casters,easy movie

weight

800Kg

Ring grave temperature

-10 °C ~ +50 °C

Relative humidity

 ≤ 95%

Altitude

2500 meters


3. Relevant standards and norms

(1) Safety of Power Sources, Reactors and Similar Products Part 1: General Requirements GB 19212.1-2008

(2) "Mechanical Safety Mechanical and Electrical Equipment Part 1: General Technical Conditions" GB 5226.1-2002

(3) "General rules for low-voltage switch gear and control equipment" GB/T 14048.1-2000

(4) "Marine diesel generator sets" GB/T 13032-2010

(5) General Specification for Loads of Military Internal Combustion Engines GJB 2815-97

(6) "General Specification for Military AC Mobile Loads" GJB 235A-97

(7) General technical conditions for industrial and intermediate frequency mobile loads GJB 235-87

(8) "General Test Method for Military Internal Combustion Engine Loads" GJB 1488-93

(9) "Design Standards for Industrial Enterprises" GBZ1200


4.Resistive load module

The resistive load module is made up of several special nickel-chromium alloy resistors. As a power consuming component, the alloy resistor is made of special alloy. The external heat sink is made of 304 stainless steel. The middle is filled with insulating medium, and the resistor is packaged in it to meet the needs of load testing. The alloy has good electrical resistance, high heat dissipation performance, uniform heat conduction, and the operating temperature is only 1/3 of the design temperature. The temperature drift is small, the resistance value is stable, and there is no red heat for a long time. It has the effects of acid and alkali resistance, salt spray resistance, rain resistance, moisture resistance and corrosion resistance, and can be used all day.

The resistive load module uses exclusive technology to fix the alloy resistance on the insulating material board. The whole module is sealed and sealed by internal insulation and insulation board to ensure insulation and safety even in wet weather. Short circuit accident caused by the decrease of internal resistance


Contact Us

Shenzhen VILVA Electronic Technology Co. Ltd.

Business Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Factory Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Phone: +86-18122867790

Contact:Amy

Fax Number 086 0755 29768581

Wechat ID:shenzhenvilva

WhatsApp:+86-15814356357

Skype:live:809b341254f5b3b8

E-mail:  pm@vilva-test.com

             3525878530@qq.com

Order:AC690V-90KW-R load bank
* Indicates required
* Product Number:
* Contact: Name
* Phone:
E-mail:
* Intent to purchase:
Please fill out the procurement of products and product descriptions to facilitate our unity stocking further.

AC230V-2KW...

AC220V-5.8...

Information
Home  | New Product  | Product  | Applications  | Case  | About Us  | News  | Contact Us
Copyright@ Shenzhen Vilva Electronics Co., Ltd. Copyright 2013 www.vilva.net 
tel:0086-755-27927879 fax:0755-29768581 Contact:Amy +86-18122867790  E-mail:pm@vilva-test.com
Add:2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C