The load overcomes the problem that the water resistance test system can't control the resistance value accurately, and the water is easy to boil and scale,can’t test with Sudden load or load reduction and not easy to control and so on.This product has high safety and low maintenance cost.Low noise, strong overload capacity.
The fan adopts a small axial fan, with large wind volume, good heat dissipation, low noise and other characteristics.
Main function and parameters
Technical parameters |
||
NO |
Parameters |
Detailed parameters |
1 |
Rated Voltage |
AC220V(± 10%),50HZ/60HZ。 |
2 |
Rated Power |
15KW,3KW,3KW,1-3KW(adjustable),1-3KW(adjustable),total 5sets. |
3 |
Power factor |
PF1.0 |
4 |
Load step |
6)Loading method: Divided gears and adjustable setting. (1):The 1st independent load box:3KW,3KW,3KW,3KW,3KW(Total 15KW) size:L*W*H 560*450*760 (2):The 2nd independent load box:1KW,1KW,1KW(Total 3KW)L*W*H/600*500*220 (3):The 3rd independent load box:1KW,1KW,1KW(total 3KW)L*W*H/600*500*220 (4):The 4th independent load box:1~3kw Continuously adjustable resistanceL*W*H/600*500*220 (5):The 5th independent load box::1~3kw Continuously adjustable resistance ,L*W*H/600*500*220 |
5 |
Load cold state power accuracy |
(±5%) |
6 |
Load test accuracy |
Display accuracy 0.5 class; Instrument sampling accuracy 0.5 class |
7 |
Work power |
Single phase AC220V/50HZ。 |
8 |
Work Mode |
Continuous work |
9 |
Cooling Mode |
Force-air cooling |
10 |
Insulation grade |
F |
11 |
Control mode |
Can be used in a single group or in parallel (two groups, three groups, four groups or five groups). |
12 |
Remote Control |
10M(or according to customer’s required) |
13 |
Move mode |
The box with a fixing hole position and a lifting hole position |
14 |
Protections |
Overheating alarm,Buzzer alarm, Overheating protection |
15 |
Ambient Temperature |
Work temperature:-20-55℃,Storage temperature:-40-85℃ |
16 |
Display and communication mode |
Each load box has voltage, current, power detection value digital table LED display, RS485 communication interface is equipped with data processing software, which can process the detection data.) |
*Insulation voltage/Insulation resistor/Leakage current required:
Subject |
Grade |
Standard(or test required) |
Insulation voltage(AC Input-ground) |
1500Vac |
can hold 1 minute, leakage current ≤ 10mA, no breakdown or arcing phenomenon |
Insulation resistor(AC Input-ground) |
100MΩ |
At normal atmospheric pressure, the relative humidity is 90%, and when the test voltage is 500Vdc. |
Leakage current |
< 3.5mA |
Input 265Vac,50Hz |
Shenzhen VILVA Electronic Technology Co. Ltd.
Business Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C
Factory Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C
Phone: +86-18122867790
Contact:Amy
Fax Number: 086 0755 29768581
Wechat ID:shenzhenvilva
WhatsApp:+86-15814356357
Skype:live:809b341254f5b3b8
E-mail: pm@vilva-test.com
3525878530@qq.com
|
|
![]() |
Copyright@ Shenzhen Vilva Electronics Co., Ltd. Copyright 2013 www.vilva.net tel:0086-755-27927879 fax:0755-29768581 Contact:Amy +86-18122867790 E-mail:pm@vilva-test.com Add:2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C |
![]() |