Home > Product > AC R Load Bank » AC220V-5.8KW-R load bank
AC220V-5.8KW-R load bank
Product Category:AC R Load Bank
Product Number:VILVA-1028
Product Brief:It can simulate various power loads and meet the needs of power supply full load detection of generator sets, UPS power supplies, inverters, etc.
Hotline:

 +86-18122867790

Product Details

Product Category: Test Load Series

Product specifications: VIVLA-AC220V-5.8KW-R load bank

Brief description: VIVLA-AC220V-5.8KW-R load bank can simulate various power loads to meet the needs of power supply full load detection of generator sets, UPS power supplies, inverters, etc.

1. The product overview

VILVA-AC220V-5.8KW-R load bank has built-in pure resistive load; it can simulate various power loads and meet the needs of power supply full load detection of generator sets, UPS power supplies, inverters, etc. It is the production workshop, laboratory, installation and commissioning. The necessary testing tools for scientific research and development.

The host has a temperature overheating automatic alarm protection function: when there is overheating due to special reasons, the load can be automatically cut off. The load works in energy-consuming mode, and the heat dissipation uses forced air cooling. The fan adopts a small axial flow fan, which has the characteristics of large air volume, good heat dissipation and low noise.

The above characteristics make the whole machine superior to imported products in terms of safety, reliability and noise reduction.


2.Technical parameters

Equipment technical parameters

Rated input voltage

AC220V

Rated input power

5.8kW

power factor

PF=1.0

Load Accuracy

±5%

Explicit System

 No

Working power supply

Single-phase AC220V/50Hz

control mode

The panel power level is controlled by a new 2P direct circuit breaker, which meets the requirement of reliable switching between AC and DC.

Insulation Grade

Class F

Protection Level

IP20 (suitable for indoor use)

Wind room noise

65 decibels

Cooling mode

Forced Axial Air Cooling: Side-in and back-out, back-out, with heat sinks punched on the panels around the load box for heat dissipation

AC/DC General Power Supply for Cooling Fan

Operation mode

Continuous operation

Protection function

Overtemperature alarm, buzzing prompt, short circuit protection

Socket interface

Standard three-core power socket, 4 channels in total, with short circuit

Connection mode

protection with protection wire

External dimensions

Each cabinet is powered by 4 outlets with 4 1.5m power lines.

temperature

- 10C~+50 ~C

Mobile mode

Hand-held; fixing bracket and handle

Applicable Relative Humidity

95%

Altitude

2500 m

Factory supplied

Appearance Fig. 1, Electrical Principle Fig. 1, Structural Diagram, Inspection Report 1, Instruction Qualification Certificate 1


3. Resistive Load Module


Resistive load module is made up of several special nickel-chromium alloy resistors. Alloy resistance, as a power dissipation component, is manufactured by special alloy processing. The heat sink made of 304 stainless steel is externally filled with insulating medium. The resistance can be encapsulated in it to meet the needs of load testing.


Alloy resistance has good insulation, high heat dissipation, uniform heat conduction, operating temperature is only 1/3 of the design temperature, small temperature drift, stable resistance, long-term work without red heat. It has the effects of acid and alkali resistance, salt fog resistance, rain proof, moisture proof and corrosion protection, and can be used all day.


Resistive load module adopts exclusive technology to fix alloy resistance on insulating material board. The whole module is sealed and treated. After isolation of internal insulation and insulating board, insulation and safety can be guaranteed even in wet weather, and short circuit accidents caused by the decrease of internal resistance of adjacent resistors can be prevented.


Contact Us

Shenzhen VILVA Electronic Technology Co. Ltd.

Business Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Factory Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C

Phone: +86-18122867790

Contact:Amy

Fax Number 086 0755 29768581

Wechat ID:shenzhenvilva

WhatsApp:+86-15814356357

Skype:live:809b341254f5b3b8

E-mail:  pm@vilva-test.com

             3525878530@qq.com

Order:AC220V-5.8KW-R load bank
* Indicates required
* Product Number:
* Contact: Name
* Phone:
E-mail:
* Intent to purchase:
Please fill out the procurement of products and product descriptions to facilitate our unity stocking further.

AC230V-2KW...

AC220V-5.8...

Information
Home  | New Product  | Product  | Applications  | Case  | About Us  | News  | Contact Us
Copyright@ Shenzhen Vilva Electronics Co., Ltd. Copyright 2013 www.vilva.net 
tel:0086-755-27927879 fax:0755-29768581 Contact:Amy +86-18122867790  E-mail:pm@vilva-test.com
Add:2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C