1、Introduction
AC380V-80KW-R load bank mainly used in the field of test AC power source such as UPS ,generator.Simulate resistive loads, and capacitive loads,It can test the performance of AC power source such as generator set and UPS under different loads. The power input is uniformly optimized to meet the needs of different loads and power factors.
Resistive load adopt new type of consumption components,Resistance thermal shrinkage and sealing installed in stainless steel tube, steel tube with insulation radiator, good moisture and corrosion resistance, good heat dissipation, high insulation, safe and reliable.High power density of resistance elements, Three phase current balance,no red heat phenomenon. The independent cooling fan ensures the heat dissipation and service life of the whole system.
The load overcomes the problem that the water resistance test system can't control the resistance value accurately, and the water is easy to boil and scale,can’t test with Sudden load or load reduction and not easy to control and so on.This product has high safety and low maintenance cost.Low noise, strong overload capacity.
The fan adopts a small axial fan, with large wind volume, good heat dissipation, low noise and other characteristics.
The above features make the whole machine superior to imported products in terms of safety, reliability and noise reduction.
2、Mainly function and parameters
NO |
Parameters |
Detailed parameters |
1 |
Rated Voltage |
Three phase 380V 50HZ/60HZ |
2 |
Rated Power |
80KW |
3 |
Power factor |
PF=1 |
4 |
Load step |
Resistive load: 27KW per phase ,RST can be divided as below: 500W/500W/1KW/2KW/3KW/5KW5KW/10KW/adjustment accuracy is 500W. |
5 |
Load accuracy |
(±5%) |
6 |
Load test accuracy |
Display accuracy 0.5 class |
7 |
sampling accuracy |
0.5 |
8 |
Work power |
Single phase AC220V/50HZ。 |
9 |
Work Mode |
Continuous work |
10 |
Cooling Mode |
Force-air cooling:Side entry, Side out |
11 |
Insulation grade |
F |
12 |
Control mode |
Manual control |
13 |
Size |
(L*W*H):900*500*1100 |
14 |
Mobile mode |
The box with a fixing hole position and a lifting hole position |
15 |
Protections |
Overheating alarm,Buzzer alarm, Overheating protection |
16 |
Ambient Temperature |
-10℃~+50℃ |
17 |
Humidity |
≤95% |
18 |
Noise |
1M from the load box<85dB . |
Shenzhen VILVA Electronic Technology Co. Ltd.
Business Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C
Factory Address: 2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C
Phone: +86-18122867790
Contact:Amy
Fax Number: 086 0755 29768581
Wechat ID:shenzhenvilva
WhatsApp:+86-15814356357
Skype:live:809b341254f5b3b8
E-mail: pm@vilva-test.com
3525878530@qq.com
Copyright@ Shenzhen Vilva Electronics Co., Ltd. Copyright 2013 www.vilva.net tel:0086-755-27927879 fax:0755-29768581 Contact:Amy +86-18122867790 E-mail:pm@vilva-test.com Add:2nd Floor,Building A2,Songhu Zhigu R&D Center,Liaobu Town,Dongguan City, Guangdong Province, P.R.C |